Material characteristic measurement system
Radar Test System


Permittivity

Permeability

Shield effect  
 
Capacitance method
Perturbation
open-resonator
S-parameter method
Free-space
     
Capacitance Method,
 
Flat Plate, Liquid, Gel, Ultra Thin Film, Compound Film, Dielectric Constant and Dielectric Loss Tangent Measurement System
System No. DPS17
Catalog No. dps17002040705-04
 
 

KEYCOM’s capacitance method/system is ideal for dielectric constant and dielectric loss tangent measurement of flat plane, liquid, or gel and
capable of taking measurements in the temperature range from liquid nitrogen
or -70 to 400 degrees Celsius.
Different types of electrodes are available for specific materials of specimens; DPT-009 for plate, thin film, gel, DPT-012, DPT-013-050 and DPT-013-200 for liquid, and DPT-2141 for ceramic insulators.
DPS17 can be interfaced with, and controlled by your PC, automating time-consuming temperature/humidity characteristics measurement.

*Windows PC is required.
*Thermostat chamber is required for temperature above or below room temperature.
ASTM D-150, JIS C2101, JIS C2141, JIS K6911 Compliant.
(Please specify the standard of your request)

 

 
Measurement frequency 1цHz ~ 10MHz (varies depending on measurement instruments)
Accuracy Dielectric constant (εr') : 1.05-1000 accuracy ±3~7% (LCR meter, mesurement environment dependent)
Dielectric loss tangent (tanδ) : 0.0003-10@1MHz accuracy ±5~15% (LCR Meter, mesurement environment dependent)
Example of LCR meter:
Basic measurement accuracy 0.05%
AC amplitude voltage 5mV-2Vrms
DC bias voltage ±40V
Impedance measurement range 1mΩ-100MΩ
Capacitance measurement range 1pF-0.01F
Measurement
temperature
(Jig dependent)
10k ~ 500˚C
*Please consult with your KEYCOM representative for more details.
*KEYCOM will suggest an appropriate cryostat of 10k~ based on its expertise in cryogenic products.
- Measurement executed automatically
- Measurement up to 100MHz is possible by modifying electrode configuration
 
Name Specifications   Model No.
Capacitance meter
(main body)
Please inform us of your frequency request
Measurement electrode Electrode for flat plate, liquid,and gel. 1цHz ~ 10MHz DPT-009
JIS compliant dielectric constant accurate
measurement tool for liquid
(JIS C2101)
1цHz ~ 100kHz DPT-012
Pipe type electrode for liquid measurement
(sample capacity, 50cc type or 200cc type)
1цHz ~ 5MHz DPT-013-050
DPT-012-200
Electrode for ceramic insulators ( JIS C 2141) 1цHz ~ 1MHz DPT-2141
In addition, KEYCOM manufactures optimum
electrode according to your request.
   
Dielectric constant analysis
software
Excel processable   DMP-002040705-05
USB type GPIB interface     GP-01
Windows PC with printer     CP
Thermostat chamber     TCOV-03
Software for thermostat
chamber
    DMP-X
 
*Measurement result is processed by PC and shown graphically, and numerical values are filed to be manipulated on EXCEL.
 
DPT-009 DPT-012
80mm φ × 180mm height Note) cables included JIS-C2101 Compliant Note) cables included
Sample shape Size and amount Capacitance (when empty) 88PF±5PF
Sheet 50μm - 2mm in thickness 30mmφ~55mmφ Liquid Volume more than 50cc
Liquid, gel more than 1cc    
 
DPT-013 DPT-2141
Note) cables included JIS-C2141 Compliant Note) cables included

with standard specimen

Model No. Liquid capacity Size Sample shape Size
DPT-013-050 50cc type 30mm φ × 100mm Seat, plate Size based on JIS-C2141
Ultra-thin film ~ 3mm thick, larger
than 37mmφ
DPT-013-200 200cc type 34mm φ × 150mm
 