Accessary
   


데이터 로거 함수 발생기 RCL 미터
 
Fluke-271
Fluke-280 Series
Fluke-290 Series
Fluke-396/397
Fluke-80/81
     
Fluke-271
 

FLUKE-271

 

271 DDS Function Generator with ARB

271 DDS Function Generator with ARB
 
Waveforms
Frequency
  All waveforms are available up to 10 MHz. However, the purity of triangle, ramp, and multi-level square wave waveforms is not specified above the frequencies indicated in the following section.
Range 0.1 mHz to 10 MHz
Resolution 7 digits or 0.1 mHz
Accuracy Typically < ± 10 ppm for 1 year, 18 °C to 28 °C
Tempco. Typically < 1 ppm/°C outside 18 °C to 28 °C
Sinewave
Distortion < –60 dBc to 20 kHz, < –50 dBc to 300 kHz, < -35 dBc to 10 MHz
Spurii Non -harmonically related spurii typically <- 60 dBc to 10 MHz
Squarewave
Rise and fall times < 22 ns
Triangle
Linearity error < 0.5 % to 30 kHz
Positive and Negative Ramp
Linearity error < 0.5 % to 30 kHz
Positive and Negative Pulse
Rise and fall times < 22 ns
Multi-Level Squarewave
  Up to 16 steps available per cycle, each step selectable for amplitude (10 bit resolution) and duration (1 to 1024 samples). Above 27 kHz a 36 ns edge uncertainty is introduced.
Rise and fall times < 22 ns
Arbitrary (and complex)
  A number of “complex” waveforms are pre-programmed in ROM . A further five, user defined, waveforms may be loaded via the digital interfaces and stored in non-volatile RAM. Frequency range: All waveform points can be continuously output up to 27 kHz, beyond which they are sampled.
No. of samples 1024 10 bit samples
Noise Wideband noise with variable amplitude and offset.
Symmetry
Range Sine — 1 % to 99 % at all frequencies; Other waveforms — 1 % to 99 % to 30 kHz,
  20 % to 80 % to 10 MHz
Resolution 0.1 %

 

 

Main Output
Output impedance
  50 Ω or 600 Ω switchable
Amplitude
  5 mV to 20 V pk-pk open circuit (2.5 mV to 10 V into 50 Ω/600 Ω). Output can be specified as V-H: 2
  (open circuit value) or V (Voltage into the characteristic impedance) in pk-pk, RMS or dBm.
  Note that in positive or negative pulse modes the amplitude range is 2.5 mV to 10 V pk-pk O/C.
Accuracy
  Typically ±3 % ±1 mV at 1 kHz into 50 Ω/600 Ω
Flatness
  ±0.2 dB to 500 kHz; ±1 dB to 10 MHz
Pulse aberrations
  <5 %+ 2 mV
DC offset
  ± 10 V from 50Ω/600 Ω offset plus signal peak limited to ± 10 V from 50 Ω/600 Ω
Resolution
  3 digits or 1 mV for both amplitude and offset

 

 

Modulation
Amplitude Modulation
Carrier frequency 0.1 mHz to 10 MHz
Carrier waveforms All
Depth 0 to 100 %, resolution 1 %
Internal source 1 kHz fixed sinewave or 0.005 Hz to 50 kHz square wave
External See “VCA In” section
Frequency Shift Keying (FSK)
  Phase coherent switching between two frequencies at a rate defined by the switching signal source
Carrier frequency 0.1 mHz to 10 MHz
Carrier waveforms All
Switch repetition rate dc to 50 kHz internal, dc to 1 MHz external
Switching signal source. Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface

 

 

Operating Modes
Trigger/burst
  Phase coherent signal keying — each positive edge of the trigger signal will produce one burst of the carrier, starting and stopping at the phase angle specified by the start/stop phase setting
Carrier frequency 0.1 mHz to 10 MHz
Carrier waveforms All
Number of cycles 1 to 1023 (resolution 1 cycle) or 0.5 to 511.5 (resolution 1/2 cycle)
Trigger rep. rate dc to 50 kHz internal, dc to 1 MHz external
Source Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface
Gated
  Non phase-coherent signal keying — output is On while Gate signal is high and Off while low.
Carrier frequency From 0.1 mHz to 10 MHz
Carrier waveforms All
Trigger rep. rate dc to 50 kHz internal dc to 1 MHz external
Gate source Internal from keyboard or trigger generator. External from EXT TRIG input or remote interface
Sweep
Carrier waveforms All
Sweep mode Linear or logarithmic, single or continuous
Sweep width 0.1 mHz to 10 MHz. Phase continuous. Independent setting of the start and stop frequency.
Sweep time 10 ms to 999 s (3 digit resolution)
Markers Two markers variable during sweep. Available at the TRIG/SWEEP OUT socket
Sweep trigger source The sweep may be free run or triggered from: keyboard, EXT TRIG input, remote interface
Hop
  Up to 16 different “hop” waveforms can be defined in terms of function, frequency, amplitude, offset and duration. Duration setable per step 1 ms to 60 s.
Start/Stop Phase
Carrier frequency 0.1 mHz to at least 1 MHz
Carrier waveforms All
Range –360 to +360 degrees
Resolution 1 degree
Accuracy Typically 1 degree to 30 kHz
Trigger Generator
  Internal source 0.005 Hz to 50 kHz squarewave adjustable in 20 us steps. 3 digit resolution. Available for external use from TRIG/SWEEP OUT socket.

 

 

Auxiliary Outputs
Aux Out
  CMOS/TTL levels with symmetry and frequency of main output and phase of start-stop phase setting
Trig/Sweep Out
  Multi-function output depending upon mode. Except in sweep mode, the output is that of the trigger generator at CMOS/TTL levels from 1 kW.
  In Sweep mode the output is a 3-level waveform, changing from high (+4 V) to low (0 V) at the start of sweep, with narrow 1 V pulses at each marker point.

 

 

Inputs
Ext Trig
Frequency range DC to 1 MHz
Signal range TTL (1.5 V) threshold; maximum input ± 10 V
Min. pulse width 50 ns
VCA In
Frequency range DC - 100 kHz
Signal range 2.5 V for 100 % level change at maximum output
Input impedance Typically 6 kΩ

 

 

Phase Locking
Clock in/out
  TTL/CMOS threshold levels; output impedance typically 50 Ω as an output
Sync out
  TTL/CMOS logic levels from typically 50 Ω. The signals from these sockets are used to phase lock two or more generators.

 

 

Interfaces
RS-232
  Variable Baud rate, 9600 Baud maximum. 9-pin D-connector.
IEEE-488
  Conforming with IEEE488.1 and IEEE488.2

 

 

General Specifications
Display
  20 character x 4 row alphanumeric LCD
Data entry
  Keyboard selection of mode, waveform etc.; value entry direct by numeric keys or by rotary control.
Stored settings
  Up to 9 complete instrument set-ups may be stored and recalled from battery-backed memory.
Size
  3U (130 mm) height; half-rack (212 mm) width, 330 mm long
Weight
  4.1 kg (9 lb)
Power
  100 V ac, 110 to 120 V ac or 220 to 240 V ac +/– 10 %, 50/60 Hz ac by internal adjustment; 30 VA max.
Operating range
  +5 °C to 40 °C, 20 to 80 % RH
Storage range
  –20 °C to +60 °C
Options
  IEEE-488 interface; 19-in rack mounting kit

 