Fluke-271
Fluke-280 Series
Fluke-290 Series
Fluke-396/397
Fluke-80/81
     
Fluke-396/397
 

FLUKE-396/397

 

Waveforms
Waveforms
  Standard waveforms: sine, square, triangle, ramp, sinc, pulse, noise, Gaussian as well as dc
Sine
Range 0.1 mHz to 50 MHz
Resolution 7 digits or 0.1 mHz
Accuracy < 1 ppm for 1 year
Temp. coefficient < 1 ppm/°C
Harmonic distortion and non related spurious below 10 MHz < 0.1 % THD to 100 kHz (2000 waveform points)
  < –55 dBc to 1 MHz
  < –40 dBc to 5 MHz
  < –35 dBc to 10 MHz
  < –22 dBc to 50 MHz
Square
Range 0.1 mHz to 50 MHz
Resolution 0.1 mHz or 7 digits
Rise and fall times < 10 ns
Triangle
Range 0.1 mHz to 12.5 MHz
Resolution 0.1 mHz or 7 digits
Accuracy 1 ppm for 1 year
Linearity error < 0.1 % to 100 kHz
Pulse
Range 0.1 mHz to 12.5 MHz
Delay 0 % to 99.9 % of period
Rise and fall times 0 % to 99.9 % of period
High time 0 % to 99.9 % of period
Resolution 0.1 %
Arbitrary Waveforms
Stored waveforms 396: Up to 4096
  397: Up to 4096 each channel
Waveform length 16 to 4 M points
Vertical resolution 14 bits
Sample clock range 100 mHz to 125 MHz
Waveform sequencing Up to 4096 segments may be linked. Minimum segment duration 1 µs. Segments can be looped up to 1,000,000 times
Amplitude
Output impedance 50 Ω
Amplitude Range 10 mVpp to 10 Vpp (20 mVpp to 20 Vpp into open circuit)
Accuracy < 1 % ± 25 mV between 1 V to 10 Vpp into 50 Ω
Flatness ± 5 % to 10 MHz; ± 20 % to 50 MHz
DC offset ± 4.5 V into 50 Ω. DC offset plus signal peak limited to ± 10 V. DC offset attenuated with amplitude range
Output Filters
  50 MHz Elliptic and 2 MHz Elliptical
Modulation Modes
Triggered burst Each active edge of the trigger signal will produce one burst of the carrier waveform, waveforms starts from point n and completes at point n-1
Gated The selected waveform is output continuously at the programmed frequency while the selected gate signal is true
Waveforms All standard and arbitrary
Carrier frequency 125 Msample/s for ARB and Sequence. 2.5 MHz or the maximum of selected waveform
No. of cycles 1 to 1,000,000
Trigger source Manual trigger key, adjacent channel or internal trigger generator or external trigger input or remote trigger command
Trigger rate Internal trigger generator: 0.1 Hz to 2 MHz; External signal: dc to 2 MHz
Start/stop phase ± 360 ° , settable to 0.1 ° subject to waveform frequency and type
Frequency sweep Manual, continuous, triggered; linear or logarithmic sweep; up or down. Variable sweep marker.
Sweep range 1 mHz to 125 MHz
Sweep time 1 ms to 999 s
Sweep trigger source External trigger input or remote trigger command
Tone switching FSK tone switching for all waveforms
External AM Via rear panel BNC input, dc-500 kHz for all standard and arbitrary waveforms

 

 

Outputs and Inputs
Main outputs
396: Single channel
397: Two channel
Sync outputs
  Front panel BNC connector generates sync pulse synchronous with output waveform. In FM and sweep modes this output is synchronous with sample clock frequencies
Ext. trigger
  DC to 2 MHz. Threshold nominally TTL level; maximum input 5 V. Selectable as positive rising edge or negative falling edge. Minimum pulse width 20 ns for trigger and gated modes
AM input
  0 V to +5 V (5 Vpp) produce 100 % modulation
Ref clock in
  Input for an external 10 MHz reference clock. Threshold nominally TTL level.
SCLK output, SCLK input and DSUB connector
  Connect instruments to achieve synchronization. DSUB 9- pin connector and cable supplied.

 

 

Inter-Channel Operation
Inter-channel modulation
  The waveform from any channel may be used to amplitude modulate (AM) the adjacent instrument/channel. Alternatively, any number of channels may be modulated (AM) with the signal at the modulation input socket.
Carrier frequency
  Entire range for selected waveform
Carrier waveforms
  All standard and arbitrary waveforms
Modulation freq.
  DC to 500 kHz
Modulation depth
  0 % to 100 %
Inter-channel synchronization
397: Both channels are tightly synchronized in phase and waveform start. Channel 2 has sample clock divider for arbitrary and sequenced waveforms.
Phase resolution
397: 1 sample clock period of channel 2
Skew error
397: ± 2 ns
Inter-instrument synchronization
  Two or more instrument may be slaved to one master instrument. Each Slave can have a unique phase resolution relative to the Master.
Phase error
  4 points
Skew error
  +/-20ns Typically with 20c"m coax cable

 

 

General Specifications
Waveform Software
  ArbExplorer Software for Windows is supplied with each instrument. This provides full waveform creation, editing and management including an equation editor, clipboard import/export and freehand drawing.
Interface types
396: GPIB and RS-232
397: GPIB, USB and Ethernet
Remote control
  Full remote control facilities are available through the interfaces
RS-232
  Variable Baud rate, 115 k Baud. 9-pin D-connector
GPIB
  Conforms with IEEE-488.1 and IEEE-488.2
Ethernet
397: Twisted pair 10/100Base-T, auto negotiation
USB
397: Type A receptacle, version 2.0
Display
396: 20 character x 4 row alphanumeric LCD
397: 3.5 in color LCD reflective, 320 x 240 pixels, back-lit
Size
  88 x 415 x 212 mm (H x D x W)
Weight
  6 kg (13 lb)
Power
  85 V to 265 V, 48 - 63 Hz, 60W
Operating temperature range
  0 °C to 50 °C
Operating humidity (non condensing)
  11 °C to 30 °C 85 % RH;
  31 °C to 40 °C 75 % RH;
  41 °C to 50 °C 45 % RH
Storage range
  –20 °C to + 60 °C
Environmental
  Operating altitude: 10,000 feet
  Storage: 15,000 feet
  Pollution degree 2
Safety
  Complies with EN61010-1
EMC
  Complies with EN61326, CE marked

 

 