Operating Modes |
Continuous |
|
Waveform runs continuously |
|
Triggered Burst |
Each active edge of the trigger signal will produce one burst of the waveform |
|
|
Carrier waveforms |
|
All standard and arbitrary |
|
Max. carrier frequency |
|
The smaller of 2.5 MHz or the maximum for the selected waveform. 100 Msamples/s for ARB or Sequence. |
|
Number of Cycles |
|
Trigger rep. rate |
|
0.005 Hz to 100 kHz internal, dc to 1 MHz external |
|
Trigger source |
|
Internal from keyboard or trigger generator. External from TRIG IN or remote interface. |
|
Start/stop phase |
|
± 360 ° settable with 0.1 ° resolution, subject to waveform frequency and type |
|
Gated |
Waveform will run while the Gate signal is true and stop while false |
|
|
Carrier waveforms |
|
All standard and arbitrary |
|
Max. carrier frequency |
|
The smaller of 2.5 MHz or the maximum for the selected waveform. 80 Msamples/s for ARB or Sequence. |
|
Trigger rate |
|
0.005 Hz to 100 kHz internal, dc to 1 MHz external |
|
Gate signal source |
|
Internal from keyboard or trigger generator. External from TRIG IN or remote interface. |
|
Start/stop phase |
|
± 360 ° settable with 0.1 ° resolution, subject to waveform frequency and type |
|
Sweep |
Capability provided for both standard and arbitrary waveforms. Arbitrary waveforms are expanded or condensed to exactly 4096 points and DDS techniques are used to perform the sweep. |
|
|
Carrier waveforms |
|
All standard and arbitrary except pulse, pulse train and sequence. Sweep mode: Linear or logarithmic, continuous or triggered. |
|
Sweep direction |
|
Up, down, up/down or down/up |
|
Sweep range |
|
1 mHz to 40 MHz in one range. Phase continuous. Independent setting of start/stop frequency. |
|
Sweep time |
|
1 ms to 999 s (3 digit resolution) |
|
Marker |
|
Sweep trig. Source |
|
The sweep may be free run or triggered from the following sources: Manually from keyboard. Externally from TRIG IN input or remote interface. |
|
Sweep hold |
|
Sweep can be held and restarted by HOLD key |
|
Tone Switching |
Capability provided for both standard and arbitrary waveforms. Arbitrary waveforms are expanded or condensed to exactly 4096 points and DDS techniques used to allow instantaneous frequency switching. |
|
|
Carrier waveforms |
|
All waveforms bar pulse, pulse train, sequence |
|
Frequency list |
|
Up to 16 frequencies from 1 mHz to 40 MHz |
|
Trigger rep. rate |
|
0.005 Hz to 100 kHz internal, dc to 1 MHz external. Usable repetition rate and waveform frequency depend on the tone switching mode. |
|
Source |
|
Internal from keyboard or trigger generator. External from TRIG IN or remote interface. |
|
Tone switching modes |
|
Gated |
|
The tone is output while the trigger signal is true and stopped, at the end of the current waveform cycle, while the trigger signal is false. The next tone is output when the trigger signal is true again. |
|
Triggered |
|
The tone is output when the trigger signal goes true and the next tone is output, at the end of the current waveform cycle, when the trigger signal goes true again. |
|
FSK |
|
The tone is output when the trigger signal goes true and the next tone is output, immediately, when the trigger signal goes true again. |
|