(주)티앤씨

본문 바로가기


거리측정기
멀티미터
범용 계측기
스코프 미터
시간 및 주파수 교정기
     
실내 공기 측정기
압력분야 교정기
열화상 카메라
온도미터
온도분야 교정기
       
전기분야 교정기
전기 측정 측정기
전력 분석기
절연저항 측정기
접지저항 측정기
       
클램프미터(후크미터)
프로세스 캘리브레이터
Accessary
   


데이터 로거 함수 발생기 RCL 미터
 
Fluke-271
Fluke-280 Series
Fluke-290 Series
Fluke-396/397
Fluke-80/81
     
Fluke-290 Series
 

FLUKE-280 Series

 

 
Arbitrary Waveforms
Waveforms
  The maximum arbitrary waveform size is 1 M points. Up to 500 user-defined waveforms may be stored on the removable memory card. Arbitrary waveforms can be defined by front panel editing controls, by downloading of waveform data via RS-232,USB or GPIB, or by writing directly to the removable memory card using the USB card reader/writer connected to a PC.
Waveform memory
  1 M points. Minimum waveform size is 8 points.
Vertical resolution
  12 bits
Sample clock range
  100 mHz to 80 MHz
Resolution
  4 digits
Accuracy
  ± 1 digit of setting
Output filter
  Selectable between 40 MHz Elliptic, 20 MHz Bessel or none
Sequence
  Up to 1024 waveforms may be linked. Each waveform can have a loop count of up to 32,768. A sequence of waveforms can be looped up to 1,048,575 times or run continuously.
Noise function
  Digital noise generated by a 35-bit linear feedback register clocked at 100 MHz. User’s external filter defines bandwidth and response

 

Standard Waveforms
Waveforms
  Sine, square, triangle, DC, positive ramp, negative ramp, sin(x)/x, pulse, pulse train, cosine, haversine and havercosine

 

 

Sine, Cosine, Haversine, Havercosine
Range
0.1 mHz to 40 MHz
Resolution
0.1 mHz or 10 digits
Accuracy
Better than 10 ppm for 1 year
Temperature stability
Typically < 1 ppm/°C
Output level
5 mV to 20 V p-p from 50 Ω
Harmonic distortion
< 0.15 % THD to 100 kHz; < –60 dBc to 20 kHz, < –50 dBc to 1 MHz, < –40 dBc to 10 MHz, < –30 dBc to 40 MHz
Non-harmonic spurii
< –60 dBc to 1 MHz, < –60 dBc + 6 dB/octave 1 MHz to 40 MHz

 

 

Square
Range
1 mHz to 50 MHz
Resolution
1 mHz (4 digits)
Accuracy
± 1 digit of setting
Output level
5 mV to 20 V p-p from 50 Ω
Rise and fall times
< 8 ns

 

 

Triangle
Range
0.1 mHz to 500 kHz
Resolution
0.1 mHz or 10 digits
Accuracy
Better than 10 ppm for 1 year
Output level
5 mV to 20 V p-p from 50 Ω, linearity error: < 0.1 % to 30 kHz

 

 

Ramps and Sin(x)/x
Range
0.1 mHz to 500 kHz
Resolution
0.1 mHz or 10 digits
Accuracy
Better than 10 ppm for 1 year
Output level
5 mV to 20 V p-p from 50 Ω
Linearity error
< 0.1 % to 30 kHz

 

 

Pulse and Pulse Train
Output level
5 mV to 20 V p-p from 50 Ω
Rise and fall times
< 8 ns
Period
Range: 40 ns to 100 s; Resolution: 4-digits; Accuracy: ± 1 digit of setting
Delay
Range: –99.9 s to + 99.99 s; Resolution: 0.001 % of period or 10 ns
Width
Range: 10 ns to 99.99 s; Resolution: 0.001 % of period or 10 ns
Trains of up to 10 pulses may be specified, each having independently defined width, delay and level. The baseline voltage is separately defined and the sequence repetition rate is set by the pulse train period.

 

 

Operating Modes
Continuous
Waveform runs continuously
Triggered Burst
Each active edge of the trigger signal will produce one burst of the waveform
Carrier waveforms
All standard and arbitrary
Max. carrier frequency
The smaller of 2.5 MHz or the maximum for the selected waveform. 100 Msamples/s for ARB or Sequence.
Number of Cycles
1 to 1048575
Trigger rep. rate
0.005 Hz to 100 kHz internal, dc to 1 MHz external
Trigger source
Internal from keyboard or trigger generator. External from TRIG IN or remote interface.
Start/stop phase
± 360 ° settable with 0.1 ° resolution, subject to waveform frequency and type
Gated
Waveform will run while the Gate signal is true and stop while false
Carrier waveforms
All standard and arbitrary
Max. carrier frequency
The smaller of 2.5 MHz or the maximum for the selected waveform. 80 Msamples/s for ARB or Sequence.
Trigger rate
0.005 Hz to 100 kHz internal, dc to 1 MHz external
Gate signal source
Internal from keyboard or trigger generator. External from TRIG IN or remote interface.
Start/stop phase
± 360 ° settable with 0.1 ° resolution, subject to waveform frequency and type
Sweep
Capability provided for both standard and arbitrary waveforms. Arbitrary waveforms are expanded or condensed to exactly 4096 points and DDS techniques are used to perform the sweep.
Carrier waveforms
All standard and arbitrary except pulse, pulse train and sequence. Sweep mode: Linear or logarithmic, continuous or triggered.
Sweep direction
Up, down, up/down or down/up
Sweep range
1 mHz to 40 MHz in one range. Phase continuous. Independent setting of start/stop frequency.
Sweep time
1 ms to 999 s (3 digit resolution)
Marker
Variable during sweep.
Sweep trig. Source
The sweep may be free run or triggered from the following sources: Manually from keyboard. Externally from TRIG IN input or remote interface.
Sweep hold
Sweep can be held and restarted by HOLD key
Tone Switching
Capability provided for both standard and arbitrary waveforms. Arbitrary waveforms are expanded or condensed to exactly 4096 points and DDS techniques used to allow instantaneous frequency switching.
Carrier waveforms
All waveforms bar pulse, pulse train, sequence
Frequency list
Up to 16 frequencies from 1 mHz to 40 MHz
Trigger rep. rate
0.005 Hz to 100 kHz internal, dc to 1 MHz external. Usable repetition rate and waveform frequency depend on the tone switching mode.
Source
Internal from keyboard or trigger generator. External from TRIG IN or remote interface.
Tone switching modes
Gated
The tone is output while the trigger signal is true and stopped, at the end of the current waveform cycle, while the trigger signal is false. The next tone is output when the trigger signal is true again.
Triggered
The tone is output when the trigger signal goes true and the next tone is output, at the end of the current waveform cycle, when the trigger signal goes true again.
FSK
The tone is output when the trigger signal goes true and the next tone is output, immediately, when the trigger signal goes true again.

 

 

External Amplitude Modulation
Carrier frequency
  Entire range for selected waveform
Carrier waveforms
  All standard and arbitrary waveforms
Modulation source
  Modulation socket
Frequency range
  DC to 500 kHz
Signal range
  Approx. 1 V pk-pk for 100 % level change at maximum output

 

 

External Signal Summing
Carrier frequency
  Entire range for selected waveform

 



회사소개 제품소개 견적및데모요청

법인명 : 주식회사 티앤씨  경기도 광명시 하안로 60, 광명SK테크노파크 A동 808호  사업자등록번호 108-81-96584  대표이사 : 김용정
  전화: 02-2635-6859   팩스: 02-6008-3672   이메일: info@tandc.co.kr

COPYRIGHT(C) 2014 TNC.ALLRIGHT RESERVED.

상단으로