(주)티앤씨

본문 바로가기


거리측정기
멀티미터
범용 계측기
스코프 미터
시간 및 주파수 교정기
     
실내 공기 측정기
압력분야 교정기
열화상 카메라
온도미터
온도분야 교정기
       
전기분야 교정기
전기 측정 측정기
전력 분석기
절연저항 측정기
접지저항 측정기
       
클램프미터(후크미터)
프로세스 캘리브레이터
Accessary
   


DHI : Flow DHI : Pressure DHI : Software Pressurements Ruska Software
 
2413 DPI Cell
2456 Piston Gauge Monitor
2465A - Gas Piston Gauge
2468A - Pitot/Static Primary Standard
2470 Gas Piston Gauge/High Pressure
2482 Differential Piston Gauge
2485 Hydraulic Piston Gauge
7050 Digital Pressure Indicators
7050i Digital Pressure Indicators
7050LP Low Pressure Indicator
7250 Digital Pressure Controller/Calibrator
7250 Sys Multi-Range Pressure Calibration System
7250 xi Digital Pressure Controller/Calibrator
7250i Digital Pressure Controller/Calibrator
7250LP Low Pressure Controller/Calibrator
7252 Dual Output Digital Pressure Controllers
7350 Pneumatic high pressure controller
7615 Hydraulic Pressure Controller
7750i Air Data Test Set AeroCal
Liquid Trap
7252 Dual Output Digital Pressure Controllers
 

 

 

The new Series 7252 provides a unique and flexible approach to performing automated calibrations over a wide pressure range. The 7252 incorporates two pressure ranges with independent controllers for each range. Therefore, two calibrations can be performed at the same time.

A wide variety of pressure range combinations can be provided from as low as 0 to 10 inH2O up to 0 - 2500 psi (25 mbar- 172 bar) providing maximum flexibility in a single instrument. Two different models are available, the 7252i and 7252. The 7252i features percent of reading performance from 25% to 100% of each installed range, whereas the economical 7252 provides 0.003% of full scale precision for each range. Both units feature a long term stability of 0.0075% of reading per year.

Similar to the single output Series 7250, the 7252 also features an active matrix color screen display with enhanced navigation menus for ease of operation. Other new features include 10 ppm control stability on each range with active and passive control modes. In active mode, the controller has the ability to make up for small leaks in the system. For systems where leaks are virtually eliminated, passive mode offers enhanced control stability by allowing the user to define a bandwidth around the set-point where the controller will shut off allowing the pressure to completely stabilize.

The Series 7252 is an ideal choice for calibrating pressure devices where a high level of throughput and performance over a wide pressure range is required.

  • Ranges from 0 - 10 inH2O to 0 - 2500 psi(25 mbar-172 bar)
  • Two performance models available, 7252i and 7252
  • Fast control : <15 seconds with zero overshoot into a 15 cu.(245cc) in. volume
  • Stability : 0.0075% of reading per year
  • Control Stability: 0.001% FS of each range
  • Labview® driver available


Pressure Ranges

Standard Pressure Ranges Model 7252i
Select two of any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 barg), or permanent absolute range from 15 to 50 psia (1 to 4 bara). Low Pressure (LP) ranges starting at 10 inH2O (25 mbarg) are also available. Please refer to the 7250LP data sheet for additional information on LP ranges and specifications.

Model 7252
Select two of any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 bar). Or, any permanent absolute range from 15 to 50 psia (1 to 4 bara).
Optional Modes Absolute using barometric reference sensor for ranges from 15 to 2500 psig (1 to 172bar)

Absolute using Vacuum Reference option for ranges from 5 to 2500 psig (400 mbar to 172 bar)
Negative gauge

Performance

Precision Model 7252i
Ranges from 5 to 2500 psi (400 mbar to 172 bar) From 25% to 100% FS: 0.005% of reading Below 25% FS: 0.005% of 25% FS

Model 7252
Ranges 5 to 2500 psi (400 mbar to 172 bar) 0.003% of FS

Model 7252i
0.36/1 psi (25/70 mbar) range: 0.005% of reading from 10% to 100% of maximum FS

Precision is defined as the combined effects of linearity, repeatability and hysteresis throughout the operating temperature range.Expression of uncertainty conforms with the recommendations of the ISO Guide to the Expression of Uncertainty in Measurement.
Stability 0.0075% of reading per year
Control Stability Active mode: 0.001% of each range
0.36/1 psi (25/70 mbar) range: 0.004% of each
Range Passive mode: No additional uncertainty
Display Resolution User selectable to 1:1,000,000
Control Response 15 seconds or less with zero overshoot into a 15 in3 (245 cc) volume in 10% increments
Negative Gauge Precision (Optional) Model 7252i
0.005% of 25% FS or 0.0005 psi* (0.0345 mbar)

Model 7252
0.003% of positive FS

*Whichever is greater
Barometric Reference (Optional) 0.002 psi (0.1379 mbar) maximum error per year
Vacuum Reference (Optional) 0.0002 psi (0.014 mbar) maximum error per year

Calibration

Calibration A calibration report with traceability to National Institute of Standards and Technology (NIST) is provided. bar). A NVLAP accredited calibration is available.

Total Uncertainty

Maximum deviation from the true value of pressure including precision, stability, temperature effects and the calibration standard Model 7252i
Ranges 0.36 to 2500 psi (25 mbar to 172 bar) (25%-100%FS)
90 day: 0.006% reading
1 year: 0.009% reading

Series 7252 Ranges 5 to 2500 psi (400 mbar to 172 bar)
90 day: RSS 0.003% FS + 0.002% reading
1 year: RSS 0.003% FS + 0.0075% reading
Control Parameters Volume:
5 to 60 cu.in. (82 to 980 cc)

Control low limit:
0 psi (0 mbar) gauge
0.15 psi (10 mbar) absolute

Communications

Communications RS232 and IEEE-488, SCPI syntax
Firmware updates are performed via RS232 interface
Drivers LabVIEW driver
MET/CAL driver optionally available

Languages

Menus and Functions The Series 7252 is capable of displaying menus and functions in: English, Japanese, French, Spanish, Chinese, Italian and German

Options

Options
  • Barometric reference (absolute and negative gauge)
  • Vacuum reference* (absolute)
  • Negative gauge only
  • NVLAP accredited calibration
  • Rack mount kit
  • MET/CAL driver
  • Intecal software
  • Liquid trap assembly
*Requires external vacuum pump

General

 Display

TFT, VGA, Active matrix, 6.4 in (163 mm), 640 X 480 resolution, 65,000 colors
Temperature Operating: 64°F to 97°F (18°C to 36°C)
Storage: -4°F to 158°F (-20°C to 70°C)
Humidity 5% to 95% relative humidity, non-condensing
Dimensions (h x w x d) All versions: 7 in X 16.5 in X 19 in (178 mm x 419 mm x 483 mm)
Weight Series 7252/7252i: 20 lb (9 kg)
Power 90 to 260 VAC, 50/60 Hz, 150 W
Test Port and Supply Connection 1/4 inch NPT female
Warm up Time 2 to 3 hours; may be left on indefinitely
Pressure Medium Nitrogen or clean dry air